Metrologic Instruments MS700i User Manual
Page 48
44
Version “26” Pin Assignments for Multi-drop RS-422
The version “26” scanner head cable is terminated with a male 25-pin D-type
connector. To connect the scanner to the host device, may require a
communication cable. The communication cable may include a connection for
a transformer or it may be designed to draw power directly from the host
device. This item can be ordered at the same time scanner is purchased.
The version “26” scanner is designed to be used for Point to Point RS-422
communication.
The following is a list of the pin assignments. The pin numbers are impressed
on the head cable’s connector.
Pin
Function
1
AC Shield Ground
2
RS-232 Receive Input
3
RS-232 Transmit Output
4
CTS Input
5
RTS Output
6
Reserved
7
Signal Ground
8
Reserved
9
Master Data +
10
Master Data -
11
Slave Data +
12
Slave Data -
13
Earth Ground
14
Power Ground 1
15
Light Pen Source
16
Light Pen Data
17
OCIA Clock In Return
18
OCIA Clock In
19
Power (11 - 30 volts) DC
20
DTR Input
21
OCIA Clock Out
22
OCIA Clock Out Return
23
OCIA RDATA
24
OCIA RDATA Return
25
Power Ground 2