beautypg.com

Metrologic Instruments MS700i User Manual

Page 39

background image

35

Operational

Depth of Field:

MS700i, MS715i

- 0.0mm - 178mm (0" - 7")

MS720i

- 178mm - 381mm (7" - 15")

Scan Speed:

MS700i, MS720i

2000 scan lines per second

MS715i

1000 scan lines per second

Scan Pattern:

MS700i, MS720i

5 scan fields: 1 horizontal, 4 at angles

MS715i

1 horizontal scan field, 10 line pattern

Projection Angle: 10

E down off perpendicular of scan window

Indicators:

LED: green=laser on; red=good read

Beeper Operation:

2 tones, 3 volume settings for “Good Read”

Maintenance Required:

Clean window periodically

Decode Capability:

Auto-discriminates

System Interfaces:

RS-232C/OCIA, Parallel, IBM 468X/469X,

®

Light Pen Emulation, Point to Point RS-422

,

PC Keyboard Wedge

Print Contrast:

35% minimum reflectance difference

Roll, Pitch, Yaw:

MS700i, MS720i

360

E, 60E, 60E

MS715i

42

E, 60E, 52E

Environmental

Storage Temperature:

-40

EC to 60EC (-40EF to 140EF)

Operating Temperature:

0

EC to 35EC (32EF to 95EF)

Humidity:

5% to 95% relative humidity, non-condensing

Light Levels:

Up to 3200 foot candles; works in direct

sunlight

Ventilation:

None required

Shock:

100g for 1ms

ESD:

15 kV IEC 801-2 Level 4

Contaminants:

Sealed to resist airborne particulate

contaminants

Specifications subject to change without notice.