CONTROL INPUT/OUTPUT SIGNALS AND CIRCUITS

2

SET/ RST/ REC IN terminals (screw)

Active:

When input terminals are short-circuited to GND or “L” level voltage (0 - +1.6V) applied.

Time for active: 0.1 sec or over.
Non active:

Open the input.

DC5V

GND

SET/RST/REC IN

0.047

µ

F

22k

10k

2

ALM/ MODE/CALL OUT terminals (screw)

Active:

“L” level voltage (0 - +0.4V) output; max. drive current 50mA(+5V DC)/
10mA(+24V DC)

Non active:

Open; max. voltage +24V DC

GND

ALM / MODE/ CALL OUT

2

CLK OUT terminal (screw)

10k

DC12V

CLK OUT

10k

GND

CLK OUT signal

• When “F” is selected in REC of CLOCK OUT mode in 3H recording.

+12V

0V

20msec

• When except “F” is selected in REC of CLOCK OUT mode in 3H recording.

+12V

0V

8msec

• During recording in L12H - 960H recording mode.

+12V

0V

10msec