Manitowoc Ice Chiplet QC0700 User Manual
Page 31
Section 2
Installation Instructions
Part Number 000002688
2-21
Installation Checklist
Is the Ice Machine level?
Has all of the internal packing been removed?
Have all of the electrical and water connections
been made?
Has the supply voltage been tested and checked
against the rating on the nameplate?
Is there proper clearance around the ice machine
for air circulation?
Has the ice machine been installed where
ambient temperatures will remain in the range of
45° - 110°F (7° - 43.3°C)?
Has the ice machine been installed where the
incoming water temperature will remain in the
range of 45° - 90°F (7° - 32.2°C)?
Are the ice machine and bin drains separately
vented?
Are all electrical leads free from contact with
refrigeration lines and moving equipment?
Has the owner/operator been instructed regarding
maintenance and the use of Manitowoc Cleaner
and Sanitizer?
Has the warranty registration card been sent to
the factory?
Has the ice machine and bin been sanitized?
Has this manual been given to the owner/
operator?
Is the water level (float valve) set correctly?
Has the toggle switch been placed in the ice
position? (Switch is located behind front cover)
REMOTE AIR-COOLED ONLY
Has the ice machine receiver service valve been
opened 100%?
Are the ice machine line set shut-off valves open
100%?
Does the condenser fan motor operate properly
after start-up?
Have all the refrigeration fittings and joints been
leak checked?
Is the line set routed properly?
Is a refrigeration oil trap (S-trap) installed?
Have the refrigeration lines been insulated and
secured properly to prevent vibration?
Has the remote condensing unit been located
where ambient temperatures will remain in the
range of -20° to 120°F (-29° to 49°C)?
Is the lineset length, rise and drop within
guidelines?