10 set features supported commands, 10 set features supported commands -7 – Maxtor D540X-4K User Manual
Page 69

ATA Bus Interface and ATA Commands
Maxtor D540X-4K 20.4/40.0/60.0/80.0 GB AT
6-7
5'6 ('#674'5 5WRRQTVGF %QOOCPFU
Table 6-2 shows the supported subcommands of SET FEATURES organized by
feature name. The ID Word column shows if the current default setting can be
80
Major version number
003Eh
81
Minor version number
0015h
82
Command set supported
346Bh
83
Command set supported
5B01h
84
Command set/feature supported extension
4003h
85
Command set/feature enabled
3468h
86
Command set/feature enabled
1A01h
87
Command set/feature default
4003h
88
Ultra DMA mode
003Fh
89
Time required for security erase unit completion
Variable
90
Time required for Enhanced security erase
completion
0000h
91
Current advanced power management value
0000h
92
Master Password Revision Code
FFFEh
93
Hardware reset result
Variable
94
acoustic management value
8080h
95-99
Reserved
Reserved
100-103
Maximum user LBA address for 48-bit Address
feature set
777Fh,
0260h,
0000h,
0000h
104-126
Reserved
Reserved
127
Removable Media Status Notification feature set
support
0000h
128
Security status
0001h
129-159
Vendor specific
Reserved
160
CFA power mode 1
0000h
161-175
Reserved for assignment by the CompactFlash™
Association
Reserved
176-254
Reserved
Reserved
255
15-8
7-0
Integrity word checksum
Integrity word signature
Variable