beautypg.com

MicroBoards Technology CWT Series User Manual

Page 14

background image

CWT Series MICROBOARDS TECHNOLOGY, LLC

14

0C

03

WRITE ERROR-RECOMMEND REASSIGNMENT

0C

07

WRITE ERROR-RECOVERY NEEDED

0C

08

WRITE ERROR-RECOVERY FAILED

0C

09

WRITE ERROR-LOSS OF STREAMING

0C

0A

WRITE ERROR-PADDING BLOCKS ADDED

11

00

UNRECOVERED READ ERROR

11

06

CIRC UNRECOVERED ERROR

15

00

RANDOM POSITIONING ERROR

15

01

MECHANICAL POSITIONING ERROR

15

02

POSITIONING ERROR DETECTED BY READ OF MEDIUM

16

00

DATA SYNCHRONIZATION MARK ERROR

16

01

DATA SYNC ERROR-DATA REWRITTEN

16

02

DATA SYNC ERROR-RECOMMEND REWRITE

16

03

DATA SYNC ERROR-DATA ATUO-REALLOCATED

16

04

DATA SYNC ERROR-RECOMMEND REASSIGNMENT

17

00

RECOVERED DATA WITH NO ERROR CORRECTION APPLIED

17

01

RECOVERED DATA WITH RETRIES

17 02

RECOVERED

DATA

WITH POSITIVE HEAD OFFSET

17 03

RECOVERED

DATA

WITH NEGATIVE HEAD OFFSET

17

04

RECOVERED DATA WITH RETRIES AND/OR CIRC APPLIED

17 05

RECOVERED

DATA

USING

PREVIOUS SECTOR ID

17 06

RECOVERED

DATA

WITHOUT

ECC - DATA AUTO-REALLOCATED

17

07

RECOVERED DATA WITHOUT ECC - RECOMMEND REASSIGNMENT

17 08

RECOVERED

DATA

WITHOUT ECC - RECOMMEND REWRITE

17

09

RECOVERED DATA WITHOUT ECC - DATA REWRITTEN

18 00

RECOVERED

DATA

WITH

ERROR CORRECTION APPLIED

18

01

RECOVERED DATA WITH ERROR CORR. & RETRIES APPLIED

18 02

RECOVERED

DATA

-

DATA AUTO-REALLOCATED

18

03

RECOVERED DATA WITH CIRC

18

04

RECOVERED DATA WITH L-EC

18 05

RECOVERED

DATA

-

RECOMMEND REASSIGNMENT

18

06

RECOVERED DATA - RECOMMEND REWRITE

18

07

RECOVERED DATA WITH ECC - DATA REWRITTEN

19

00

DEFECT LIST NOT ERROR

19

01

DEFECT LIST NOT AVAILABLE

19

02

DEFECT LIST ERROR IN PRIMARY LIST

19

03

DEFECT LIST ERROR IN GROWN LIST

1A

00

PARAMETER LIST LENGTH ERROR

1B

00

SYNCHRONOUS DATA TRANSFER ERROR

1C

00

DEFECT LIST NOT FOUND

1C

01

PRIMARY DEFECT LIST NOT FOUND

1C

02

GROWN DEFECT LIST NOT FOUND

1D

00

MISCOMPARE DURING VERIFY OPERATION

20

00

INVALID COMMAND OPERATION CODE

21

00

LOGICAL BLOCK ADDRESS OUT OF RANGE

21

02

INVALID ADDRESS FOR WRITE

24

00

INVALID FIELD IN CDB

25

00

LOGICAL UNIT NOT SUPPORTED

26

00

INVALID FIELD IN PARAMETER LIST

26

01

PARAMETER NOT SUPPORTED

26

02

PARAMETER VALUE INVALID

26

03

THRESHOLD PARAMETERS NOT SUPPORTED

26

04

INVALID RELEASE OF ACTIVE PERSISTENT RESERVATION

27 00

WRITE

PROTECTED

27

01

HARDWARE WRITE PROTECTED

27

02

LOGICAL UNIT SOFTWARE WRITE PROTECTED

27

03

ASSOCIATED WRITE PROTECT

27

04

PERSISTENT WRITE PROTECT

27

05

PERSISTENT WRITE PROTECT

27

06

CONDITIONAL WRITE PROTECT

28

00

NOT READY TO READY CHANGE, MEDIUM MAY HAVE CHANGED

29

00

POWER ON, RESET, OR BUS DEVICE RESET OCCURRED