beautypg.com

Error codes, Read errors – MicroBoards Technology CWT Series User Manual

Page 11

background image

CWT Series MICROBOARDS TECHNOLOGY, LLC

11

Error Codes

Read Errors

ASC ASCQ

Description

00

00

NO ADDITIONAL SENSE INFORMATION

00

06

I/O PROCESS TERMINATED, PLAY OPERATION ABORTED

00

11

AUDIO PLAY OPERATION IN PROGRESS

00

12

AUDIO PLAY OPERATION PAUSE

00

13

AUDIO PLAY OPERATION SUCCESSFULLY COMPLETED

00

14

AUDIO PLAY OPERATION STOPPED DUE TO ERROR

00

15

NO CURRENT AUDIO STATUS TO RETURN

00 17

CLEANINF

REQUESTED

01 00

NO INDEX/SECTOR SIGNAL

02

00

NO SEEK COMPLETE

04

00

LOGICAL UNIT NOT READY, CAUSE NOT REPORTABLE

04

01

LOGICAL UNIT IS IN PROCESS OF BECOMING READY

04

02

LOGICAL UNIT NOT READY, INITIALIZING CMD. REQUESTED

04

03

LOGICAL UNIT NOT READY, MANUAL INTERVENTION REQUIRED

04

07

LOGICAL UNIT NOT READY, OPERATION IN PROGRESS

05

00

LOGICAL UNIT DOES NOT RESPOND TO SELECTION

06

00

NO REFERENCE POSITION FOUND (medium may be upside down)

08

00

LOGICAL UNIT COMMUNICATION FAILURE

08

01

LOGICAL UNIT COMUUNICATION TIME-OUT

08

02

LOGICAL UNIT COMMUNICATION PARITY ERROR

08

03

LOGICAL UNIT COMMUNICATION CRC ERROR (ULTRA-DMA/32)

09

00

TRACK FOLLOWING ERROR

09

01

TRACKING SERVO FAILURE

09

02

FOCUS SERVO FAILURE

09

03

SPINDLE SERVO FAILURE

0A

00

ERROR LOG OVERFLOW

0B 00

WARNING

0B 01

WARNING-SPECIFIED

TEMPERATURE EXCEEDED

0B 02

WARNING-ENCLOSURE

DEGRADED

10

00

ID CRC OR ECC ERROR

11

01

UNRECOVERED READ ERROR

11

02

ERROR TOO LONG TO CORRECT

11

05

L-EC UNCORRECTABLE ERROR

11

06

CIRC UNRECOVERED ERROR

11

0F

ERROR READING UPC/EAN NUMBER

11

10

ERROR – LOSS PF STREAMING

12

00

ADDRESS MARK NOT FOUND FOR ID FIELD

13

00

ADDRESS MARK NOT FOUND FOR DATA FIELD

14

01

RECORD NOT FOUND

14

05

RECORD NOT FOUND – RECOMMEND REASSIGNMENT

14

06

RECORD NOT FOUND – DATA AUTO – REALLOCATED

15

00

RANDOM POSITIONING ERROR

15

01

MECHANICAL POSITIONING ERROR

15

02

POSITIONING ERROR DETECTED BY READ OF MEDIUM

17 00

RECOVERED

DATA

WITH

NO EEOR CORRECTION APPLIED

17

01

RECOVERED DATA WITH RETRIES

17 02

RECOVERED

DATA

WITH POSITIVE HEAD OFFSET

17 03

RECOVERED

DATA

WITH NEGATIVE HEAD OFFSET

17 04

RECOVERED DATA WITH RETIES AND/OR CIRC APPLIED

17 05

RECOVERED DATA USING PREVIOUS SECTOR ID

18 00

RECOVERED

DATA

WITH

ERROR CORRECTION APPLIED

18

01

RECOVERED DATA WITH ERROR CORP. & RETRIES APPLIED

18

03

RECOVERED DATA WITH CIRC

18

04

RECOVERED DATA WITH L-EC

1A

00

PARAMETER LIST LENGTH ERROR

1B

00

SYNCHRONOUS DATA TRANSFER ERROR

1E

00

RECOVERED ID WITH ECC CORRECTION