Installing the DAG 500 blower box
on the rear
The blower box can also be installed on
the back of the ventilation system:
^ Remove the large cover on the rear.
Mounting is the same as if installing
on the front.
^ Mount the blower on the rear the
same way as described for mounting
on the front.
^ When finished, mount the previously
removed cover on the front.
Preparing the exhaust air connection
^ When using an exhaust diameter of
5" (125 mm) secure the reduction
adapter with tape and confirm that
there is an air-tight connection.