(5) When the AJ65SBT-64AD "L ERR." LED flickers at fixed intervals

Check item

Corrective action

Has the station number or transmission speed

setting switch position been changed during normal

operation?

After correcting the setting switch setting, switch

power on again.

Is the station number or transmission speed setting

switch faulty?

If the "L ERR." LED has begun flickering though

switch setting change was not made during

operation, the possible cause is a hardware fault.

Contact your nearest Mitsubishi representative.

(6) When the AJ65SBT-64AD "L ERR." LED flickers at unfixed intervals

Check item

Corrective action

Have you forgotten fitting the terminal resistor?

Check whether the terminal resistor is fitted. If it is

not connected, connect it and switch power on

again.

Is the module or CC-Link dedicated cable affected

by noise?

Earth both ends of the shield wire of the CC-Link

dedicated cable to the protective earth conductor

via SLD and FG of the corresponding module.

Earth the FG terminal of the module without fail.

When carrying out wiring in piping, earth the pipe

without fail.

(7) When the AJ65SBT-64AD "L ERR." LED is on

Check item

Corrective action

Are the station number and transmission speed

correct?

Set the correct station number and transmission

speed.