beautypg.com

Electrical connection 46, Electrical connection – Miele G7859 User Manual

Page 50

background image

Electrical connection

All electrical connection work must be
carried out by a qualified electrician in
compliance with local and national
regulations.

For extra safety it is advisable to in-
stall a residual current device (RCD)
with a trip current of 30 mA.

Technical data is available on the
data plate or in the enclosed wiring
diagram.

The voltage, rated load and plug rating
must correspond to that given on the
data plate.

Conversion can only be undertaken in
compliance with the conversion and
wiring diagrams and only on machines
without a steam condenser.

A conversion diagram is to be found at
the back of the machine and on the
back of the service panel.

The relevant wiring diagram is to be
found on the left-hand side behind the
plinth, attached to the base of the ma-
chine.

The data plate with the relevant test cer-
tification is on the rear of the machine
and on the plinth (behind the service
panel).

To remove the service panel and
plinth:

Disconnect the machine from the
mains.

Remove fixing screws “

a

”.

Take hold of both sides of the ser-
vice panel and pull forward.
Remove plinth fascia screws “

b

”.

Disconnect earth lead if necessary.
Remove plastic protective cap.

To reassemble:

Replace plastic protective cap,
plinth fascia and service panel in
reverse order.

Make sure the earth lead is recon-
nected.

Also refer to the installation instructions
enclosed.

Electrical connection

46