beautypg.com

Programming special functions 33, Programming special functions – Miele G7859 User Manual

Page 37

background image

Programming special functions

In the event of a service call at a later
date, any changes made to the fac-
tory setting should be documented
here.
Make a note of any changes made in
the “Value set:

” box.

1. Setting the cold water inlet from:
“Nominal water intake” to “Nominal
water intake + 1 l”.

The amount of water taken into the ma-
chine at each intake can be increased
by 1 litre to a maximum of 9.5 litres.

Proceed as follows:

Turn the programme selector to the
f “STOP” position.

Switch off the machine.

Press 4 and

6 at the same time,

hold them in and whilst doing so
switch the machine on with the

I-0

button.
The current programme status “P...”
appears in the display.
The

p / 6 indicator light comes on.

Press 3 once, “E01” (programming
level 1) appears in the display.

Turn the programme selector to the
p position,
“10” or “11” appears in the display.
“10” = Nominal water intake
“11” = Nominal water intake + 1 l

Press 4 to change from “10” to
“11” or vice versa.

Press

6. “SP” appears in the display.

Press

6 again. The change has

been recorded.

Value set:

2. Selecting a second interim rinse

A second interim rinse can be pro-
grammed in to improve interim rinsing
in all programmes (except D COLD).

Turn the programme selector to the
f “STOP” position.

Switch off the machine.

Press 4 and

6 at the same time,

hold them in and whilst doing so
switch the machine on with the

I-0

button.
The current programme status “P...”
appears in the display.
The

p / 6 indicator light comes on.

Press 3 once, “E01” (programming
level 1) appears in the display.

Turn the programme selector to r ,
“30” or “31” appears in the display.
“30” = One interim rinse.
“31” = Two interim rinses.

Press 4 to change from “30” to
“31” or vice versa.

Press

6. “SP” appears in the display.

Press

6 again. The change has

been recorded.

Value set:

Programming special functions