8. resetting fan belt safety shutdown – Miller Electric Miller DU-OP User Manual
Page 43
OM-494 Page 39
8-8. Resetting Fan Belt Safety Shutdown
158 715 / Ref. 158 632 / Ref. 190 377
Y Stop engine.
1
Cooling Fan V-Belt
See engine manual to replace or
tighten belt.
If belt breaks or becomes loose,
safety shutdown stops engine.
Correct problem, then reset safety
shutdown as follows:
2
Rod
3
Stop
4
Bracket
5
Handle
Pull handle towards front of unit un-
til stop snaps in position behind
bracket.
Close door.
1
3/8 in
Right Side
5
2
3
4
Tools Needed:
Pull Handle To
Reset Shutdown