OM-494 Page 17

5-6. Safety Information For Connecting To Weld Output Terminals

Y UNEXPECTED WELD OUTPUT can cause injury or fire.

D Both weld outputs can be live (ON) when Welder Selector switch is in Welder A/Welder B position and engine is running.
D Disconnect or insulate any unused cables.
D Know where cables are located BEFORE starting engine.

Y ELECTRIC SHOCK can kill; ARCING can burn skin or damage electrical connections.

D Stop engine before making any weld output connections.
D Do not connect welding output of different polarities to the same structure.
D See ANSI Z49.1 and OSHA Title 29, Chapter XVII, Part 1910, Subpart Q (addresses at beginning of manual).
D When welding on the same workpiece, all connections to the workpiece must be of the same polarity.
D Do not handle or come in contact with two live electrodes at the same time.

Y ELECTRIC SHOCK can kill; TWO TIMES NORMAL OPEN-CIRCUIT VOLTS can exist between electrode holders of opposite polarity.

D Do not touch electrode holders of opposite polarity at the same time.
D Separate electrode holders of opposite polarity to prevent contact.
D Consult ANSI Z49.1 for common grounding safe practices.

5-7. Weld Output Terminals

Ref. 190 377 / 802 292-A / 802 554

Y Stop engine.
1

Negative (−) Weld Output Terminal

2

CV Weld Output Terminal

3

CC Weld Output Terminal

4

Dinse Weld Receptacles (Only On

Units With Polarity Switch Option)

See Sections 5-8 thru 5-13 for dual operator

output connections for CC and CV welding.

See Section 5-14 for single operator output

connections (CC only).
If unit has the Polarity switch option, the

Negative (−) weld output terminals are la-

beled Work receptacles and the CC weld

output terminals are labeled Electrode re-

ceptacles.

Tools Needed:

3/4 in

Welder B (Right) Side

1

2

3

Welder A (Left) Side

1

2

3

.

Dinse receptacles only on units
with Polarity switch option.

4