OM-494 Page 33
SECTION 8 − MAINTENANCE & TROUBLESHOOTING
8-1. Routine Maintenance
Y Stop engine before maintaining.
.
See Engine Manual and Maintenance Label
for important start-up, service, and storage
information. Service engine more often if
used in severe conditions.
Recycle engine
fluids.
n = Check
Z = Change
~ = Clean
l = Replace
* To be done by Factory Authorized Service Agent
Reference
Every
8
Hours
FUEL
WATER
n Fuel/Water Separator
n Fuel Level
n Oil Level
~ Oil, Fuel Spills
Every
50
Hours
~ Air Cleaner Element
~ Weld Terminals
Every
100
Hours
~ Battery Terminals
n Air Cleaner Hoses
Z Oil Z Oil Filter
Every
250
Hours
Engine
Manual,
l Unreadable Labels
n~Spark Arrestor
Every
500
Hours
nl Weld Cables
Every
1000
Hours
1/2 in.
(13 mm)
OR
FUEL
SLUDGE
8-10 and
Engine
Manual
n Fan Belt Tension
~ Inside Unit
Z FuelFilter
~ Drain Sludge
n~ Slip Rings*
nl Brushes*
nValve Clearance*