When facing the front panel, the Welder B

controls and weld terminals are on the

right and the Welder A controls and weld terminals are on the left.

NOTE

5-1. Installing Welding Generator

install1 11/02* − Ref. ST-800 652 / Ref. ST-800 477-A / ST-158 936-A / S-0854

Electrically bond generator frame to

vehicle frame by metal-to-metal

contact.

GND/PE

1

2

Y Always securely fasten welding

generator onto transport vehicle

or trailer and comply with all DOT

and other applicable codes.

Y Always ground generator frame

to vehicle frame to prevent elec-

tric shock and static electricity

hazards.

Y If unit does not have GFCI recep-

tacles, use GFCI-protected ex-

tension cord.

1

Equipment Grounding Terminal

(On Front Panel)

2

Grounding Cable (Not Supplied)

3

Metal Vehicle Frame

Connect cable from equipment ground

terminal to metal vehicle frame. Use #10

AWG or larger insulated copper wire.
Y Be sure equipment connected to

the 240 V receptacles is GFCI-

protected.

3

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

OR

Movement

Airflow Clearance

Location

Grounding

OR

Y Do Not Lift Unit From End

Y Bed liners, shipping skids, and some running

gears insulate the welding generator from the

vehicle frame. Always connect a ground wire

from the generator equipment grounding termi-

nal to bare metal on the vehicle frame as shown.