Monarch Instrument 9830TM User Manual
Page 14

Printer Overview and Installation
9820/9830/9835 Service Manual
July 1998
TC9830SM Rev. B 7/98 Confidential
5
Table 1 - 2. Exterior Rear (SW2 and SW3) DIP Switch Settings
Upper DIP Switches:
SELECTION
1
2
3
4
5
6
7
8
DEFAULT
Baud Rate
38400
ON ON OFF
19200
ON OFF ON
9600
ON OFF OFF
9600
4800
OFF ON ON
2400
OFF ON OFF
1200
OFF OFF ON
Software Ctrl
OFF OFF OFF
Data Bits
7 Data Bits
ON
8 Data Bits
OFF
8 Data Bits
Stop Bits
2 Stop Bits
ON
ON Stop Bit
OFF
1 Stop Bit
Parity
Even
ON OFF
Odd
OFF ON
None
OFF OFF
None
Parallel Port
Centronics Mode
OFF
Centronics
IEEE-1284
ON