17. Reinstall the rubber
cover. Be sure that the
cover lip surrounds
the valve completely
and that the tab is
inserted through the
cover.
18. Check the drink tube for cuts, abra-
sions, or other signs of damage. Grasp
the knurled surface and pull the tube
out of the cover to check it for signs of
damage. Be sure the tube is reinstalled
in its port completely.
19. Reinstall the voice-
mitter gasket in the
side port. Be sure that
it is flat.
20. Place the voice-mitter into the port.
Note:
The voice-mitter's crimped side faces
out (up).
21. Thread the retaining ring into the port
and tighten using the spanner wrench.
22. Place the deflector (with the inhalation
valve in place on the post) into the face-
piece.
23. Line up the deflector
so that it is between
the guide tabs molded
into the facepiece.
24. While holding the deflector in place,
press the spider gasket on to the post
from outside the facepiece.
25. Insert the gasket
groove into the port
so that the groove
captures the lip of the
port completely. Run
your finger around the
gasket to be sure the
gasket lays flat.
26. Thread the cartridge/canister into the
port. (see Preparing the Respirator for
Use section)
27. If any part is damaged or deteriorated, it
must be replaced. Store only undam-
aged respirators for further use. When
not in use, store the respirator in cool,
dry, and clean ambient air. Keep new fil-
ters in their packing.
TAL 403 (L) Rev. 4 - 430351
22
INSPECTION
Guide Tabs