beautypg.com

MicroNet Technology SP1659P User Manual

Page 71

background image

: 0 or 1

Example:

SP1659P(802.1x)# set mode 2 1

SP1659P(802.1x)#

set port-control

Syntax: set port-control

Description: To set up 802.1X status of each port.

Argument:

: syntax 1,5-7, available from 1 to 24

: Set up the status of each port

0:ForceUnauthorized

1:ForceAuthorized

2:Auto

Possible value:

: 1 to 24

: 0, 1 or 2

Example:

SP1659P(802.1x)# set port-control 2 2

set quiet-period

Syntax:

set quiet-period

Description:

A timer used by the Authenticator state machine to define periods of time during when it will not attempt to

acquire a Supplicant.

Argument:

: syntax 1,5-7, available from 1 to 24

: timer , range 0-65535

Possible value:

: 1 to 24

: 0-65535, default is 60

Example:

SP1659P(802.1x)# set quiet-period 2 30

set reAuthEnabled

Syntax: set reAuthEnabled

Description: A constant that define whether regular reauthentication will take place on this port.

Argument:

: syntax 1,5-7, available from 1 to 24

:

0:OFF Disable reauthentication

1:ON Enable reauthentication

Possible value:

: 1 to 24

: 0 or 1, default is 1

Example:

SP1659P(802.1x)# set reAuthEnabled 2 1

set reAuthMax

70