System – MicroNet Technology SP1659P User Manual
Page 111
22 DISCARDING 2000000 128 No Auto
23 DISCARDING 2000000 128 No Auto
24 DISCARDING 2000000 128 No Auto
show status
Syntax: show status
Description: To display the status of STP.
Argument: None
Possible value: None
Example:
SP1659P(stp)# show status
STP Status :
STP State : Enabled
Bridge ID : 00:11:3B:D8:09:1D
Bridge Priority : 61440
Designated Root : 00:11:3B:D8:09:1D
Designated Priority : 61440
Root Port : 0
Root Path Cost : 0
Current Max. Age(sec) : 20
Current Forward Delay(sec) : 15
Hello Time(sec) : 2
STP Topology Change Count
: 0
Time Since Last Topology Change(sec) : 848
4.3.24 system
set contact
Syntax: set contact
Description: To set the contact description of the switch.
Argument:
Possible value:
Example:
SP1659P(system)# set contact Taipei
set device-name
Syntax: set device-name
Description: To set the device name description of the switch.
Argument:
Possible value:
Example:
SP1659P(system)# set device-name CR-2600
set location
Syntax: set location
Description: To set the location description of the switch.
Argument:
Possible value:
Example:
SP1659P(system)# set location Taipei
110