beautypg.com

Maxtor Digital Video Recorder CBC V 0.4 User Manual

Page 14

background image

alarm triggered, COM disconnect with NC, and connect with NO.

PIN 8. EXTERNAL ALARM NO

Under normal operation COM connect with NC and disconnect with NO. But when

Alarm triggered, COM disconnect with NC, and connect with NO.

PIN 9. GND

GROUND

PIN 10. RS485-B

DVR can be controlled remotely by an external device or control system, such as a

control keyboard, using RS485 serial communications signals.

PIN 11. RS485-A

DVR can be controlled remotely by an external device or control system, such as a

control keyboard, using RS485 serial communications signals.

PIN 12. DISK FULL

When HDD is full, it sends a signal to trigger next DVR record mode, if you install

another DVR. Under normal operation, the signal remains “High”. But when disk full,

DVR will send the “Low” signal.

PIN 13. ALARM RESET

To connect wire from ALARM RESET ( PIN 13 ) to GND ( PIN 9 ) connector, it can

disable ALARM. An external signal to ALARM RESET ( PIN 13 ) can be used to

reset both ALARM OUTPUT signal and DVR’s internal buzzer. When alarm has

been triggered, signal becomes “Low”, and it will stop all alarm activities. Under

normal operation, signal remains “High”.

PIN 14. ALARM INPUT

To connect wire from ALARM INPUT ( PIN 14 ) to GND ( PIN 9 ) connector, DVR

will start recording and buzzer will be on. When alarm has been triggered, signal

becomes “Low”, and it will stop all alarm activities. Under normal operation, signal

remains “High”.

PIN 15. COM

Under normal operation COM connect with NC and disconnect with NO. But when

alarm triggered, COM disconnect with NC, and connect with NO.

4. Power input

Connect to power cord (standard package attached).

3.4 Menu

setup

14