Manitowoc Ice Q User Manual
Page 39
Section 4
Maintenance
Part Number 000001530
4-3
D. Remove the water distribution tube
•
Remove the clamp from the vinyl water hose on the
right side of the distribution tube.
Water Distribution Tube Removal
•
Loosen the two thumbscrews which secure the
distribution tube.
SU1024YC - Loosen the three thumbscrews, which
secure the distribution tube.
•
Lift the right side of the distribution tube up, and then
rotate it backward and to the right until the left side of
the distribution tube disengages the thumbscrew.
•
Pull the vinyl hose off the distribution tube.
Disassemble for cleaning:
•
Twist both of the inner tube ends until the tabs line up
with the keyways.
•
Pull the inner tube ends outward.
E. Remove the water level probe
•
Pull the water level probe straight down to
disengage.
•
Disconnect the wire lead from the water level probe.
•
Remove the water level probe from the ice machine.
! Caution
Do not force this removal. Be sure the locating tab is
clear before rotating the distribution tube back.
SV1620
1. LIFT UP
2. SLIDE BACK
3. SLIDE TO RIGHT
DISTRIBUTION
TUBE
THUMBSCREW
THUMBSCREW
LOCATING
PIN
3
2
1
21-Jan-99
21-Jan-99
WATER LEVEL
PROBE
LOCATION