Installation Instructions

Section 2

2-8

Part Number 000001530

QuietQube® Ice Machine Head Section Electrical Wiring Connections

115/1/60

230/1/50

!

Warning

These diagrams are not intended to show proper
wire routing, wire sizing, disconnects, etc., only the
correct wire connections.

All electrical work, including wire routing and
grounding, must conform to local, state and national
electrical codes.

Though wire nuts are shown in the drawings, the ice
machine field wiring connections may use either
wire nuts or screw terminals.

L

1

L

1

N=115V

OR

L2=208-230V

GROUND

GROUND

ICE MACHINE

CONNECTIONS

SV1258

L

1

L

1

N

N

GROUND

GROUND

ICE MACHINE

CONNECTIONS

TO SEPARATE

FUSE/BREAKER.

DISCONNECT ALL

POLES.

SV1191

For United Kingdom Only

As the colours of the wires in the mains lead of the appliance may not correspond with the coloured markings
identifying the terminals in your plug, proceed as follows:

The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with
the letter E or by the earth ground symbol

or coloured green or green and yellow.

The wire coloured blue must be connected to the terminal which is marked with the letter N or coloured black.

The wire coloured brown must be connected to the terminal which is marked with the letter L or coloured red.