beautypg.com

Dca-180ssv— generator shut-down procedures – Multiquip MQ Power Whisperwatt 60 Hz Generator DCA-180SSV User Manual

Page 39

background image

DCA-180SSV— OPERATION AND PARTS MANUAL — REV. #1 (04/14/10) — PAGE 39

1

Normal Shutdown Procedure

To shutdown the generator use the following procedure:

1. Place both the MAIN, GFCI and LOAD circuit breakers

as shown in Figure 38 to the OFF position.

2. Place the engine speed switch (Figure 54) in the “

LOW

(down) position.

Figure 55. MPEC Control Switch (Off/Reset)

5. Verify that the

all status LED on the MPEC display

are OFF (not lit).

6. Remove all loads from the generator.

7. Inspect entire generator for any damage or loosening of

components that may have occured during operation.

DCA-180SSV— GENERATOR SHUT-DOWN PROCEDURES

3. Let the engine cool by running it at low speed for 3-5

minutes with no load applied.

4. Place the

MPEC Control Switch (Figure 55) in the

OFF/RESET position.

Figure 54. Engine Speed Switch (Low)

NEVER stop the engine suddenly except in an emergency.

WARNING - SHUTTING DOWN THE GENERATOR

Emergency Shutdown Procedure

1. To stop the engine in the event of an emergency place

the

MPEC Control Switch (Figure 55) in the

OFF/RESET position.

This manual is related to the following products: