Motor data, Power code description — psh models, Power code description — bsh models – Modine Manufacturing 6-558.6 User Manual
Page 18: Unit power requirements - blower bsh models, Heater parts from acf greenhouses

18
MOTOR DATA
Power Code Description — PSH Models ➀ ➂ ➃
Model
PSH130
PSH150
PSH170
PSH225
PSH280
PSH340
Power
Electric
Code
Power
Horsepower
01
115/60/1
1/6
1/6
1/6
1/3
1/2
1/2
02
230/60/1
1/6
1/6
1/6
1/3
1/2
1/2
04
200/60/3
1/3
1/3
1/3
1/3
1/2
1/2
05
200/460/60/3
1/3
1/3
1/3
1/3
1/2
1/2
Power Code Description — BSH Models ➁ ➂ ➃ ➄
Power
Model
BSH130
BSH150
BSH170
BSH225
BSH280
BSH340
Code
Electric Power
HP
Drive
HP
Drive
HP
Drive
HP
Drive
HP
Drive
HP
Drive
01
115/60/1
1/3
-13
3/4
-18
3/4
-18
3/4
-18
1
-16
1-1/2
-16
02
230/60/1
1/3
-13
3/4
-18
3/4
-18
3/4
-18
1
-16
1-1/2
-16
03
200-208/60/3
1/3
-13
3/4
-18
3/4
-18
3/4
-18
1
-16
1-1/2
-16
04
230/460/60/3
1/3
-13
3/4
-18
3/4
-18
3/4
-18
1
-16
1-1/2
-16
81
575/60/3
1/3
-14
3/4
-18
3/4
-18
3/4
-18
1
-16
1-1/2
-178
05
115/60/1
1/4
-21
1/2
-25
1/2
-25
3/4
-22
1
-18
1
-29
06
230/60/1
1/4
-21
1/2
-25
1/2
-25
3/4
-22
1
-18
1
-29
07
200-208/60/3
1/4
-21
1/2
-25
1/2
-25
3/4
-22
1
-18
1
-29
08
230/460/60/3
1/4
-21
1/2
-25
1/2
-25
3/4
-22
1
-18
1
-29
82
575/60/3
1/4
-165
1/2
-25
1/2
-25
3/4
-22
1
-18
1
-29
09
115/60/1
1/3
-15
1/2
-22
1/2
-22
1
-16
1-1/2
-23
10
230/60/1
1/3
-15
1/2
-22
1/2
-22
1
-16
1-1/2
-23
11
200-208/60/3
1/3
-15
1/2
-22
1/2
-22
1
-16
1-1/2
-23
2
-32
12
230/460/60/3
1/3
-15
1/2
-22
1/2
-22
1
-16
1-1/2
-23
2
-32
83
575/60/3
1/3
-166
1/2
-22
1/2
-22
1
-16
1-1/2
-177
2
-32
13
115/60/1
1/3
-57
3/4
-25
14
230/60/1
1/3
-57
3/4
-25
15
200-208/60/3
1/3
-57
3/4
-25
16
200/460/60/3
1/3
-57
3/4
-25
84
575/60/3
1/3
-167
3/4
-25
Motor Data and Total Unit Power Requirements — PSH Models
Voltage
115/60/1
230/60/1
200-208/60/3
230/460/3
Motor
Motor
Total
Total
Motor
Motor
Total
Total
Motor
Motor
Total
Total
Motor
Motor
Total
Total
HP
Amps
Rpm
Amps
Watts
Amps
Rpm
Amps
Watts
Amps
Rpm
Amps
Watts
Amps
Rpm
Amps
Watts
1/6
2.8
1075
4.6
400
1.5
1075
2.5
400
1/3
5.4
1075
7.2
610
2.5
1075
3.5
610
1.9
1140
2.8
560
2.2/1.1
1140
3.2/1.6
560
1/2
7.5
1075
9.3
800
3.5
1075
4.5
800
2.6
1140
3.5
850
3.0/1.5
1140
4.0/2.0
850
Unit Power Requirements - Blower BSH Models
115/60/1
230/60/1
200-208/60/3
230/460/60/3
575/60/3
➄
Total
Total
Total
Total
Total
Total
Total
Total
Total
Total
HP
Amps
Watts
Amps
Watts
Amps
Watts
Amps
Watts
Amps
Watts
1/4
7.2
520
3.7
520
2.5
500
2.4/1.2
500
0.9
500
1/3
6.4
515
3.3
515
2.7
530
2.6/1.3
530
1.1
530
1/2
10.3
730
4.8
730
3.4
730
3.6/1.8
730
1.3
730
3/4
12.8
1000
6.5
1000
4.1
970
3.8/1.9
970
1.5
970
1
15.2
1210
7.7
1210
4.9
1230
4.8/2.4
1230
1.9
1230
1-1/2
16.8
1690
8.5
1690
6.5
1630
6.2/3.1
1630
2.3
1630
2
-
-
-
-
8.6
2080
7.6/3.8
2080
2.7
2080
➀
Permanent split capacitor motors on models PSH130 through PSH340.
➁
Split phase motors for 1/4 through 3/4 hp motors. Capacitor start motors are 1 through 2 hp.
➂
Whenever 230V/1
φ
or 230V/3
φ
power is used, it is necessary to specify 230V/25V controls. Whenever 460V/3
φ
power is used, it is necessary to specify 230V/25V
controls and in addition, a 460V/230V 75VA step-down transformer (by others) is required. On 230V/3
φ
or 460V/3
φ
systems, the motor starter coil voltage (motor
starter by others) must be 230V. For 200V/3
φ
systems, the motor starter coil voltage (motor starter by others) must be 200V.
➃
All motors used are produced, rated and tested by reputable manufacturers in accordance with NEMA standards and carry the standard warranty of both the motor
manufacturer and Modine. All motors are totally enclosed. Single phase motors have built-in thermal overload protection.
➄
575V motor available on blower units only.
Voltage