At 65°F ambient and unit fired at full rated input. Max mounting height as measured from bottom of unit, and without deflector hoods.
➄
Note: Ratings shown are for elevations up to 2,000 feet. For elevations above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea
level. (In Canada see Rating Plate.) Reduction of ratings requires use of high altitude kit.
➅
Data listed is for standard 115-volt, 60-Hertz, single-phase motors. All single phase motors are totally enclosed and thermal overload protected.
A
H
D (OPENING)
BB
E
AA
B
K
W
X
F
C
CC
DD
J
L
(MIN. DISTANCE TO WALL)
➁
GAS SUPPLY
CONNECTION
2
7/
8
"
FF
G
EE
3
3/
8
"
3
1/
8
"
4" ROUND FOR
PSH 130 thru 225
MODELS ONLY
COMBUSTION AIR
INLET COLLAR
(SIZES 280 & 340)
COMBUSTION AIR
INLET COLLAR
(SIZES 130-225)
3
1/
8
"
4
1/
2
"
OVAL COLLAR FITS
6" ROUND PIPE FOR
MODELS PSH 280 & 340 ONLY
K
The minimum recommended installation clearance from
top and rear of unit (motor) is six inches. Clearance to
sides is eighteen inches, and clearance at bottom should
equal “C” dimension shown in table for each model.
DO NOT USE PROPELLER UNITS WITH DUCT WORK.
Dimensions (in inches) — PSH
Performance—PSH
Dimension
PSH 130
PSH 150
PSH 170
PSH 225
PSH 280
PSH 340
A
23-1/2
25-5/8
25-5/8
28-5/8
33-5/8
40
B
35-1/2
40-1/2
40-1/2
40-1/2
40-1/2
40-1/2
C
22
25
25
25
25
25
D
21-1/16
23-3/16
23-3/16
26-3/16
31-3/16
37-1/2
E
20
24
24
24
24
24
F
12-1/2
14-1/2
14-1/2
14-1/2
—
—
G
1
2
2
2
1-5/8
1-5/8
H
19-7/8
22
22
25
30
36-3/8
AA
8
9
9
9
9
9
BB
7 1/2
7-1/2
7-1/2
7-1/2
7-1/2
7-1/2
CC
1
1/8
1/8
1/8
1-3/8
1-3/8
DD
3-1/4
3-1/4
3-1/4
3-1/4
3-5/8
3-5/8
EE
32-9/16
36
36
36
36-1/16
36-1/16
FF
6-1/2
6-1/2
6-1/2
6-1/2
5-7/8
5-7/8
J (Round)
4
4
4
4
6
6
K ➀
3/8-16
3/8-16
3/8-16
3/8-16
3/8-16
3/8-16
Natural Gas Connections ➂
1/2
1/2
1/2
1/2
3/4
3/4
W
—
—
—
—
5
5
X
—
—
—
—
16
16
L
38-3/8
42
42
42
42
48
Fan Diameters
18
20
20
22
22
24
Approx. Ship. Wt.
198
244
246
272
328
422
➀
PSH 130 through PSH 225 — 2 holes.
PSH 280 & PSH 340 — 4 holes.
➁
Dimension from rear of unit burner box to center line of gas pipe connection is 6-23/32" for PSH 130 and 6-1/2" for all other models.
➂
For natural gas.
Btu/Hr
Air
Max. Mtg.
Heat
Standard Motor Data ➅
Input
Btu/Hr
CFM
Outlet
Temp.
Height
Throw
Model
➄
Output
@ 70°F
Velocity
Rise
(Ft.) ➃
(Ft.) ➃
HP
Amps
RPM
Type
PSH 130
130,000
106,600
2540
940
39
12
50
1/6
2.8
1075
PSC
PSH 150
150,000
123,000
2900
810
39
16
50
1/6
2.8
1075
PSC
PSH 170
170,000
139,400
2900
820
45
16
50
1/6
2.8
1075
PSC
PSH 225
225,000
184,000
4275
1060
40
20
65
1/3
5.4
1075
PSC
PSH 280
280,000
229,600
4400
960
48
20
65
1/2
6.8
1075
PSC
PSH 340
340,000
275,400
5300
980
48
20
65
1/2
6.8
1075
PSC
SEPARATED COMBUSTION PROPELLER UNIT HEATERS