Checking input rate, Heater parts from acf greenhouses – Modine Manufacturing 6-558.6 User Manual
Page 13

13
CHECKING INPUT RATE
Pilot Orifice Identity Numbers
Pilot Burner
Identity No.
Identity No.
Manufacturer
Natural Gas
Propane Gas
Honeywell
BCR-18
BCR-11 or -12
Robertshaw
Johnson
7715
4710
1
8
N
➁
1
O
P
L
➁
As number appears on top of pilot orifice.
Table 6
Orifice Drill sizes with Decimal Equivalents
Main Burner Orifices
Dia.
Dia.
Drill
Decimal
Drill
Decimal
Size
Equivalent
Size
Equivalent
19
.1660
37
.1040
21
.1590
39
.0995
22
.1570
40
.0980
24
.1520
41
.0960
27
.1440
43
.0890
29
.1360
44
.0860
Table 5
Manifold Pressure & Gas Consumption
➀
Natural
Propane
Typical Heating Value (BTU/Cu.Ft.)
1040
2500
No. of
Model
Specific Gravity
0.60
1.53
Orifices
Manifold Pressure inches w.c.
3.5
10.0
Cfh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
125
52
PSH130
Gal/Hr. Propane . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
—
1.42
BSH130
Sec/cu.ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
29
69
2
Orifice Drill Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
24
41
Cfh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
144
60
PSH150
Gal/Hr. Propane . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
—
1.64
BSH150
Sec/cu.ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25
60
3
Orifice Drill Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
29
44
Cfh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
163
68
PSH170
Gal/Hr. Propane . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
—
1.86
BSH170
Sec/cu. ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25
60
3
Orifice Drill Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27
43
Cfh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
216
90
PSH225
Gal/Hr. Propane . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
—
2.46
BSH225
Sec/cu.ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17
40
3
Orifice Drill Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19
37
Cfh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
269
112
PSH280
Gal/Hr. Propane . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
—
3.06
BSH280
Sec/cu. ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13
32
4
Orifice Drill Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21
39
Cfh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
327
136
PSH340
Gal/Hr. Propane . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
—
3.72
BSH340
Sec/cu. ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
26
5
Orifice Drill Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
22
40
➀
Above gases based on average standards. Units can be furnished for gases of different values and specific gravities. (Gas/Hr. Propane based on 60°F, 30" Hg, 91,500
Btu/Gal.
➁