beautypg.com

Fla i – Magnetek 144-45117-R3 User Manual

Page 11

background image

Regenerative

Power

Module

-

September

2010

144-45117-R3

Page 11 of 20

Resistor Sizing

The minimum connected resistor to the standard RPM module is 1 ohm. The resistor value can be greater
than this but never lower. Use the following procedure to calculate the continuous current rating of the
resistor chosen.


1.

Tabulate all motion Full Load Amps (FLA)

• ½ hour FLA for hoist motion
• 1 hour FLA for travel motions

2.

Calculate Regen Current for simultaneous motion operation

3.

Size RPM Unit(s) and external resistors as close as possible to calculated value.



















+

=

3

.

0

*

8

.

0

*

TRAVEL

HOIST

REGEN

FLA

FLA

I