beautypg.com

Troubleshooting – Multiquip Submersible Pump ST2010 Series User Manual

Page 21

background image

ST2010 SerieS SubmerSible pump • operaTion and parTS manual — rev. #3 (12/07/12) — page 21

trOubleshOOting

Troubleshooting (pump)

Symptom

possible problem

Solution

Pump Fails To Start

Incorrect voltage/amps?

Check that proper voltage is being supplied to

the pump. Also check that there is an adequate

amount of current (amps) to run the pump.

Check power source circuit breaker.

Check electrical connections?

If using fl oat switches check wiring, inspect

power cord.

Blown power fuse?

Replace fuse, check cause of blown fuse.

Impeller locked?

Disconnect power cord and check for clogging

and improper impeller clearance. Unclog pump.

Check overload protection device.

Wet motor windings?

Use multimeter to check motor insulation.

Insulation resistance must be greater than 15

megaohms. If resistance is low, disassemble

pump motor and bake windings to dry them.

Defective motor and pump bearings? Check for excessive bearing wear. If worn,

replace bearings. Replace motor if defective.

Pump Fails to Deliver Full

Output

Twisted or restricted discharge hose? Lay hose fl at unkinked. Remove clog from hose

line.

Clogged pump strainer?

Clean strainer.

Low voltage?

Use a voltmeter to check voltage while pump

is energized. Voltage must be within ±10%.

Check power source (no load and load).

If an extension cord is used, make sure it

has adequate current-carrying capacity for

the required length.See Cord Length and

SizesTable.

Impeller worn?

Replace impeller.

Water in Seal Oil

Defective water seal?

Replace water seal.

Loose Oil Fill Plug?

Tighten securely.