beautypg.com

Operation – Multiquip Submersible Pump ST2010 Series User Manual

Page 16

background image

page 16 —ST2010 SerieS SubmerSible pump • operaTion and parTS manual — rev. #3 (12/07/12)

OperatiOn

HoSe ConneCTionS

Connect a 2-inch hose to the discharge port on the pump

as shown in Figure 9. Make sure that the hose is attached

correctly to the discharge port.

pump poWer ConneCTionS

(piggY-baCk Cord onlY)

1. Make sure the circuit breaker supplying power to the

pump is in the OFF position.

2. Connect the float switch or switches to the AC power

receptacle as shown in Figure 6.

aTTaCHing liFTing rope

1. Attach a suitable lifting cable (rope) to the carrying

handle (Figure 9) on the pump and lower the pump

into place. For applications where there is an excessive

amount of mud, grit or silt, the use of a support platform

is desirable. When pumping water from swimming pool

type applications where there is little or no debris, the

support platform is not required.

Figure 9. Submersible Pump Upright

(Correct Position)

2. Make sure the pump is always placed in an upright

position, not tilted (Figure 10). Never position the pump

directly on a soft, loose bottom. Remember to attain

maximum pumping capacity and prevent excessive

wear, position the pump so it will not burrow itself into

sand or clay.

Figure 10. Submersible Pump Tilted

(Incorrect Position)

3. If all of the pump's electrical requirements have been

met, place the circuit breaker or power ON/OFF switch

in the ON position.

4. Wait a few seconds and water should begin to flow

from the discharge hose.

5. If water is not flowing from the discharge hose or not

flowing freely after a few minutes, remove the power

from the pump and check the system for leaks.

6. To stop the pump from pumping, place the circuit

breaker or ON/OFF switch in the OFF position.

Figure 11. Power Cord (Wet Hands)

danger

never grab or touch a live power cord (Figure 11).

do noT stand in water when connecting the pump's

power cord into a voltage source. The possibility exists

of electrical shock, electrocution and possibly death!

POWER

CORD

(POWER ON)

WET

HANDS

This manual is related to the following products: