Components – Multiquip Submersible Pump ST2010 Series User Manual

Page 11

background image

ST2010 SerieS SubmerSible pump • operaTion and parTS manual — rev. #3 (12/07/12) — page 11

COMpOnents

ST2010, ST2010a, ST2010b, ST2010Cul

ST2010TCul

6

5

2

3

1

4

7

8

9

Figure 2. Submersible Pump Components

Figure 2 shows the location of the basic components for

the ST2010 series submersible pumps. Listed below is a

brief description of each component.
1.

Strainer base — Made of chrome-plated steel which

is resistant to hardware corrosion.

do noT pump

large objects or debris with this pump. This pump is

for pumping water only. Always place the strainer base

on a platform.

2.

volute/impeller — Volute is constructed of cast iron

and impeller is made of cast ductile iron to minimize

wear and prolong service life.

3.

electric motor — All ST2010 series submersible

pumps utilize a 60 Hz, single-phase, 1.0 HP electric

motor. The ST2010, ST2010A, ST2010CUL and

S-2010TCUL operate at 115 VAC while the ST2010B

operates at 230VAC. Consult with a licensed electrician

before connecting motor to a power source. Observe

all city and local safety codes.

4.

discharge port — Connect a 2-inch hose to this port.

Remember to adequately support the discharge hose

to avoid stress on the pump.

5.

aC power Cable — This unit is supplied with an AC

power cable. Always check the cable for signs of wear.

never use a defective power cable. Replace the cable

immediately if the cable is worn or defective.

6.

Carrying Handle — Always carry the submersible

pump by its handle.

never carry the pump by its

power cord. Carrying or lifting the pump by the power

cord will cause undue stress on the cord and ultimately

the cord will become dislodged from the pump.

7.

Thermal overload protection — This pump is

equipped with thermal overload protection device that

will shut down the motor in the event of high operating

temperatures. The motor will automatically restart once

the temperature returns to an acceptable operating

temperature.

8.

mechanical oil Seal — This oil-filled seal provides

lubrication when running the pump dry.

never run

the pump dry. Running the pump dry will cause severe

damage to the pump.

9.

mechanical oil Seal plug — Remove this plug to

check and add hydraulic oil (Shell 32 or equivalent)

to the oil cavity. This oil protects the mechanical seal.

Oil cavity should be full enough to cover seal spring.