Page 62: Detail description, Definition range

background image

A - 6

TM

APP. A
STAR …

CODES

(HEX/CONTROL) : 19 /

FUNCTION :

Immediate drive command for peripheral unit 2

APPLICATION LIMIT :

Peripheral units 1 and 2 cannot be driven

simultaneously.

DETAIL DESCRIPTION :

Drives peripheral unit 2. Pulse width is fixed

at 200ms with a fixed delay time of 200ms. Same as .

CODES

(HEX/CONTROL) : 1A /

FUNCTION :

Immediate drive command for peripheral unit 2

APPLICATION LIMIT :

Peripheral units 1 and 2 cannot be driven

simultaneously.

DETAIL DESCRIPTION :

Drives peripheral unit 2. Pulse width is fixed

at 200ms with a fixed delay time of 200ms.

CODES

(HEX/CONTROL) : 1B 07 n1 n2 / n1 n2

FUNCTION :

Adjust drive pulse width for peripheral unit 1

DEFINITION RANGE :

1

n1 ≤ 127, 1 ≤ n2 ≤ 127

APPLICATION LIMIT :

Adjustment is not necessary for standard cash

drawers in the U.S.A. market.

DETAIL DESCRIPTION :

Adjusts drive pulse width for peripheral

device #1 requiring other than standard 200 ms pulse time and recovery time.

Energizing time = 10 x n1 ms
Recovery time = 10 x n2 ms
Executed by or code.

Printing and paper feed are prohibited throughout the energizing and recovery
time.

CODES

(HEX/CONTROL) : 1B 25 00 / “%” <0>

FUNCTION :

Disable download character set

DETAIL DESCRIPTION :

Disable the selected download character set

and selects the built-in character set. When the power for the printer is initially
turned on, the built-in character set is selected.