Codes, Function, Application limit – Mustek PP3000 User Manual
Page 62: Detail description, Definition range

A - 6
TM
APP. A
STAR …
CODES
(HEX/CONTROL) : 19 /
FUNCTION :
Immediate drive command for peripheral unit 2
APPLICATION LIMIT :
Peripheral units 1 and 2 cannot be driven
simultaneously.
DETAIL DESCRIPTION :
Drives peripheral unit 2. Pulse width is fixed
at 200ms with a fixed delay time of 200ms. Same as .
CODES
(HEX/CONTROL) : 1A /
FUNCTION :
Immediate drive command for peripheral unit 2
APPLICATION LIMIT :
Peripheral units 1 and 2 cannot be driven
simultaneously.
DETAIL DESCRIPTION :
Drives peripheral unit 2. Pulse width is fixed
at 200ms with a fixed delay time of 200ms.
CODES
(HEX/CONTROL) : 1B 07 n1 n2 /
FUNCTION :
Adjust drive pulse width for peripheral unit 1
DEFINITION RANGE :
1
≤ n1 ≤ 127, 1 ≤ n2 ≤ 127
APPLICATION LIMIT :
Adjustment is not necessary for standard cash
drawers in the U.S.A. market.
DETAIL DESCRIPTION :
Adjusts drive pulse width for peripheral
device #1 requiring other than standard 200 ms pulse time and recovery time.
Energizing time = 10 x n1 ms
Recovery time = 10 x n2 ms
Executed by
Printing and paper feed are prohibited throughout the energizing and recovery
time.
CODES
(HEX/CONTROL) : 1B 25 00 /
FUNCTION :
Disable download character set
DETAIL DESCRIPTION :
Disable the selected download character set
and selects the built-in character set. When the power for the printer is initially
turned on, the built-in character set is selected.