beautypg.com

Codes, Function, Detail description – Mustek PP3000 User Manual

Page 61

background image

A - 5

TM

APP. A
STAR …

CODES

(HEX/CONTROL) : 13 /

FUNCTION :

Set deselect mode

DETAIL DESCRIPTION :

1. When using serial interface printer

This function differs depending on the setting of DIP switch 4.
a) When the DC1, DC3 invalid mode is set (DIP switches 4-1 to 4-4 are all

set to ON), the printer ignores this code.

b) In the DC1, DC3 valid mode (with DIP switches 4-1 to 4-4 set to OFF),

data following this code is ignored when the printer receives a
code.

The deselect mode is canceled by code.

c) If the printer receives a code during an addressable mode (with

DIP switches 4-1 to 4-4 set to settings other than a) and b) above), the data
following this code is ignored.

Deselect mode can be canceled by a n code.

Note that addressable mode is valid only when the RS-422A interface
option is installed.

2. When using parallel interface printer

Data following this code is ignored when the printer receives a code.
The deselect mode is canceled by code.

CODES

(HEX/CONTROL) : 14 /

FUNCTION :

Cancel expanded character mode

DETAIL DESCRIPTION :

Cancel expanded character mode set by

code (Data following this code is printed out in normal size characters).

CODES

(HEX/CONTROL) : 18 /

FUNCTION :

Cancel print data in buffer

DETAIL DESCRIPTION :

1. When using serial interface printer

Clears the data buffer and the line buffer

Clears the data buffer in the STX-ETX mode, and terminates the STX-ETX
mode.

2. When using parallel interface printer

Clears the data buffer and the line buffer