V.8/v.8bis commands – Multi-Tech Systems MT5600SMI-34 User Manual
Page 63

Chapter 5 – AT Commands, S-Registers, and Result Codes
Multi-Tech Systems, Inc. SocketModem MT5600SMI Developer’s Guide
63
V.8/V.8bis Commands
Command:
+A8E
V.8 and V.8bis Operation Controls
Description:
This command is defined for two conditions: as a parameter while the
modem is on-hook, and as an action command while the modem is off-
hook. If enabled, V.8 negotiation does not preclude simultaneous
implementation of other negotiation means (e.g., V.8bis, V.18, V.32bis
Annex A).
This command is a compound parameter if issued while the modem is on-
hook, used to precondition V.8 and V.8bis originating and answering
operation. It is issued by the DTE before the Dial (D) or Answer (A)
command, regardless of the state of the +FCLASS parameter.
This command is an action command if issued while the modem is off-
hook, to (re)start V.8 or V.8bis negotiation. For example, if initial V.8
negotiation failed, but subsequent T.30 negotiation indicated V.8 capability,
this command may be used to initiate V.8 negotiation.
Defined Values:
indications during modem-controlled V.8 origination negotiation.
1
Enable DCE-controlled V.8 origination negotiation without
+A8x indications. (Default.)
6
Enable DCE-controlled V.8 origination negotiation with +A8x
indications.
indications during modem-controlled V.8 answer negotiation.
1
Enable DCE-controlled V.8 answer negotiation without +A8x
indications. (Default.)
5
Enable DCE-controlled V.8 answer negotiation with +A8x
indications.
00 (Default.)
21
C1
0 Disable
V.8bis
negotiation.
1
Enable V.8bis negotiation. (Default.)
Not supported.
< protrange >= “
Not supported.
Default values:
1,1,00,1,0,0
The ATD and ATA commands behave as specified in V.250, and +A8n
indications are not generated by the modem.
For subparameter values
issued during the course of the V.8 session to notify the DTE when the
relevant V.8 signals are received.
Report Commands:
+A8E? Reports Current or Selected Values.
Response: +A8E:
Example: +A8E: 1,1,00,1,0,0 For the defaults
+A8E=? Reports Supported Range of Parameter Values.
Response: +A8E: (
(
Example: +A8E: (1,6),(1,5),(0,21,C1),(0,1),(0),(0)