Command: +VTD
Beep Tone Duration Timer
Description:
This command causes the modem to set the default DTMF/tone generation
duration.
Syntax:
+VTD=
Defined Values:
in units of 0.01 second. A value of 0 specifies the value entered by the S11
parameter (50-255 ms). The range is 0.01 to 2.55 seconds for
255.
Reporting Current or Selected Values:
Command: +VTD?
Response:
Example: 100 For the default setting.
Reporting Supported Range of Parameter Values:
Command: +VTD=?
Response: (
Example: (0-255)
Result Codes:
OK
ERROR Otherwise, or if not in Voice Mode.
Command: +VDR
Distinctive Ring
Description:
This command causes the modem to enable or disable reporting of the ring
cadence information and to control the timing of the RING event code report if
ring cadence reporting is enabled.
Syntax:
+VDR=
Defined Values:
0 The modem will not report ring cadence information.
1 The modem will report ring cadence information as specified for the
enabled by the
0 The modem will produce only DROF and DRON messages. The modem will
not produce any RING event codes. The modem will report other call progress
event codes as normal.
Other The modem will produce only DROF and DRON messages. The
modem will produce a RING event code after
falling edge of the ring pulse (i.e., after the DRON report).
Reporting Current or Selected Values:
Command: +VDR?
Response:
Example: 0,0 For the default setting.
Reporting Supported Range of Parameter Values:
Command: +VDR=?
Response: (
Example: (0,1),(0-6)
Result Codes:
OK