Section 6 – Installation

PRIMEPACT 66G and 66LP Recreational Vehicle Generators

• Vapor seal all compartment seams and joints.
• Over the galvanized steel lining, install a combination

of acoustical materials as mentioned in Section 6.2.3.

To prevent fire or explosion, do not install any
insulation or other absorbent materials on the
interior or underside of the compartment floor.

• Seal all compartment door edges to prevent noise

leakage around the door perimeter.

• Line the compartment door interior (except for air

openings) with suitable, fireproof sound insulation
(such as 1-inch (25 mm) thick fiberglass with a 2-
pound density).

Figure 6.7 – Typical Noise Abatement

Figure 6.8 — Compartment Floor Cutout