Installation instructions, Technical specification, Packing checklist – Stovax Steel Manhattan Log Effect Stove Range User Manual
Page 8
![background image](/manuals/113139/8/background.png)
8
INSTALLATION INSTRUCTIONS
TECHNICAL SPECIFICATION
COVERING THE FOLLOWING MODELS:
STEEL MANHATTAN 8618LUC (AN/MA/BS) – P8618LUC (AN/MA/BS)
Model
Gas
Gas
Working
NOX
Aeration
Injector
Gas Rate
Input kW (Gross) Country
CAT.
Type
Pressure
Class
m
3
/h
High
Low
8618LUC
I
2H
Natural
20 mbar
3
Ø 14.5
375
0.623
6.6
3.6
GB, IE
(G20)
Gross
Gross
P8618LUC
I
3P
Propane
37 mbar
3
Ø 11.5 x 2
165
0.232
6.4
3.6
GB, IE
(G31)
Gross
Gross
Packing Checklist
Qty Description
1
Stove
1
Flue Blanking plate
1
Coal Retainer
1
Log set (5 logs)*
1
Ash Panel (2 sections)*
1
Fixing Kit Containing
1 Instruction Manual
1 Wood Screw
1 Rawplug
1 Box spanner
*Packed in appliance
1
AR1318
Efficiency Class II
Flue Outlet Size 127mm (5”) Ø
Gas Inlet Connection Size 8mm Ø
Minimum Flue Specification T260 / N2 / 0 / D / 1
Maximum Flue Temperature 180°C