Air Requirements

An adequate supply of combustion and ventilation air is

required to:

• Ensure proper combustion.

• Reduce risk of property damage, severe bodily injury or

death from possible flue gas leakage and carbon

monoxide emissions.

Do not install an exhaust fan in the same room as the water

heater.

Satisfactory combustion cannot be sustained in an area that

is not provided with fresh air. Fresh air contains oxygen that

is necessary for proper combustion. If the water heater is

installed in a confined space, sufficient fresh air must be

drawn in from outside of the enclosure.

NOTE: Lack of adequate fresh air supply may cause a

poor flame.

Air Supply

In Canada:

If the water heater is installed in a house built to the require-

ments of the “National Building Code of Canada, 1985”,

or a subsequent edition, the space shall be provided with a

air inlets as outlined below, or have a mechanical air-supply

system of sufficient equivalent capacity. If a mechanical air-

supply system is used, it shall be interlocked to the appli-

ance or equipment.

NOTE: In unconfined spaces in buildings of conventional

frame, brick, or stone construction built prior to the require-

ments of the “National Building Code of Canada, 1985”,

and not subsequently significantly air-tightened, infiltration is

normally adequate to provide air for combustion and some

ventilation; however, there may be notable exceptions.

Houses built in accordance with the “National Building

Code of Canada, 1985” (or subsequent edition), with exten-

sive exterior stucco coating, or with a sealed vapour barrier

or other similar air sealing technique, will often be sufficient-

ly airtight so that there is not sufficient air for both combus-

tion and venting the products of combustion of an oil-fired

appliance, or for replacing the air vented by other exhaust

devices within the house.

Outdoor Combustion & Ventilation Air

(Unconfined space)

If the water heater is installed in an unconfined space in a

building having insufficient infiltration, additional air for com-

bustion and ventilation shall be obtained from outdoors or

from spaces freely communicating with the outdoors. Under

these conditions, permanent opening(s) shall be provided so

that the total air received through these openings will be at

least as much as would be admitted by openings having a
total free area of 4.5 cm

2

/kWh (1 in

2

/5000 Btu/h) of the total

input rating of all oil-fired appliances.

Outdoor Combustion & Ventilation Air

(Confined space)

A heater installed in a confined space that obtains all of its

air for combustion and ventilation from outside the building

shall be provided with two permanent openings, one near

the top of the enclosure and another near the bottom. Each

opening shall communicate directly or by means of ducts

with the outdoors or to such spaces (such as a crawl space)

that freely communicate with the outdoors, and shall be

sized in accordance with “Air Duct Sizing”.

Outdoor Combustion Air & Indoor Ventilation

Air (Confined space)

An appliance located in a confined space that obtains its

combustion air from outdoors and ventilation air from within

the conditioned space of the building shall be provided with

two permanent openings for ventilation. One located near

the top of the enclosure and another near the bottom. Each

opening shall have a free area of not less than 19.5
cm

2

/kWh (1 in

2

/1000 Btu/h) of the total input rating of all

OIL

STORAGE

TANK

VENT

FILL CAP

LEVEL

GAUGE

SERVICE

SWITCH

AQUASTAT

CUT OFF VALVE

OIL FILTER

DRAFT

REGULATOR

BLOCKED VENT

SAFETY SWITCH

T&P VALVE

OPERATING

INSTRUCTIONS

OIL

BURNER

Figure 4 INSTALLATION DIAGRAM

RISE 20mm/m

(1/4 in./ft.)

CAUTION

IF AN ALL-HOUSE VENTILATION FAN IS USED, A

SEPARATE OUTSIDE AIR DUCT MUST BE USED AND

DUCTED TO THE FURNACE ROOM AND/OR ROOM

WHERE THE WATER HEATER IS LOCATED.