beautypg.com

Warning – GSW JWF307 User Manual

Page 3

background image

– 3 –

Relief Valve Requirements

For protection against excessive pressure and/or tempera-

tures, an ASME approved Temperature and Pressure (T&P)

Relief Valve must be installed in the opening provided and

labeled near the hot water outlet. Pressure rating of the

valve must not exceed the working pressure shown on the

rating plate of the water heater. The discharge capacity of

the T&P valve must be equal to or greater than the input

capacity of the water heater. The valve shall be self closing.

This product contains fiberglass wool and ceramic fiber

materials. Airborne fibers from these materials have been

listed by the State of California as a possible cause of can-

cer through inhalation. Use special care when handling

ceramic fiber (chamber lining and base insulation) materials.

Ceramic fibers can be converted to chrystobalites, a sub-

stance listed as a probable cause of cancer. Suppliers of

fiberglass wool products recommend the following mea-

sures be taken when handling these materials:

Precautionary measures:

• Avoid breathing fiberglass dust.

• Avoid contact with skin and eyes.

• Use a National Institute for Occupational Safety and

Health (NIOSH) approved dust/mist respirator.

• Wear long-sleeved, loose fitting clothing, gloves and eye

protection.

• Wash work clothes separately from other clothing. Rinse

washer thoroughly.

Removing the burner may generate airborne fiber concen-

tration requiring additional protection.

First aid measures:

• Eye contact - Flush eyes with sterile water to remove

foreign objects. If irritation or other symptoms persist,

seek medical attention.

• Skin contact - Wash affected areas gently with soap and

warm water after handling.

Fuel Specifications

All JOHN WOOD brand water heaters are designed to burn

only fuels not heavier than No.2 (furnace) oil.

Location

NOTICE:

Before installing this water heater, consideration

and planning must be given to the following details:

Routing and support of the vent piping.

How and where to obtain combustion and ventilation air

supply; See “Air Requirements”.

Access to oil supply, See “Oil Supply Connections”.

Position of water supply, floor drain and placement of

water piping for hot and cold water; See “Water Supply

Connections”.

Connection to the electrical service. See “Electrical

Supply Connections”.

The water heater must be installed on a non-combustible

floor, as close to the chimney as practical and close to the

water piping. The unit should be installed in an area not sub-

ject to freezing temperatures. It should be located so that all

controls and drains are easily accessible (at least 610mm

(24 in.) clearance in front of the water heater). Check the

area around the installation location. Remove any com-

bustible materials, gasoline and other flammable liquids.

Failure to keep area clear and free of such materials and

vapors can result in substantial property damage, severe

bodily injury or death.

The heaters for which this manual has been written have

been approved with the minimum clearances to com-

bustibles as listed in Figure 1.

Unpacking and Inspection

Move the water heater to the location of installation before

removing the exterior packaging. Remove exterior packag-

ing and place installation components aside. Inspect all

parts for damage prior to installation and start-up.

Completely read and understand all instructions before

attempting to assemble and install this product. If you

observe damage to the water heater or any of its compo-

nents, DO NOT ASSEMBLE OR INSTALL IT OR MAKE ANY

ATTEMPT TO FIX THE DAMAGED PART(S). Contact the

place of purchase for further instructions.

Important: Do not remove any permanent instructions,

labels, or the date label from the outside of the water heater

or on the inside of panels. After installation, dispose of pack-

aging material in the proper manner.

II) SAFETY

CAUTION

POSSIBLE CANCER HAZARD BY INHALATION. CAN

CAUSE RESPIRATORY, SKIN AND EYE IRRITATION.

· Do not use gasoline, crank case oil or an oil

containing gasoline.

· Do not tamper with unit or controls.

· Do not leave paper or rags around the

burner or heater.

· Do not experiment with the burner.

WARNING

III) INSTALLATION

Excessive Weight Hazard

Use two or more people to move and install

water heater. Failure to do so can result in

back or other injury.

WARNING

This manual is related to the following products: