beautypg.com

GSW JWF307 User Manual

Page 12

background image

– 12 –

Startup

MAKE SURE THAT THE HEATER IS FULL OF WATER.

See “Filling the Water Heater” section.

DO NOT ATTEMPT TO START BURNER IF ANY OF THE

FOLLOWING CONDITIONS EXIST:

1. Excess oil has accumulated.

2. The unit is full of vapours.

After the installation is finished and the installation checklist

completed, proceed as follows:

1. Set the draft regulator for full draft.

2. Turn on oil at the tank. Adjust the air band on the burner

according to the instructions provided by the burner

manufacturer.

3. Close the inspection cover on the burner mounting

panel, and press the reset button on the combustion

safety control.

4. Set electric switch to “ON” position. The burner should

start.

5. Make the air adjustment and take the necessary com-

bustion test readings as specified by the burner manu-

facturer.

Filling the Water Heater

Do not turn "ON" the electrical supply to the water heater

until all the following steps, including “Startup” steps, have

been completed.

1. Make sure the drain valve is closed.

2. Open a hot water faucet associated with the system.

3. Open the cold water supply valve.

NOTE: When filling, avoid water leakage. Do not allow the

insulation of the water heater to get wet as water can cause

electrical malfunction.

4. When water runs out of the hot water faucet in a steady

stream, the tank is full.

5. Close the hot water faucet and check the system for

leaks. Repair as required and retest.

6. Connect a hose to the drain valve and route to a suitable

drain. Open the drain valve and let water run to flush out

any foreign matter that may have entered the system.

Once flushed, close the drain valve and disconnect hose.

Repeat steps 2-5.

Installation Checklist

NOTE: refer to the instruction manual sup-

plied with the burner for installation, start up

and adjustment.

Check Here

1.

Have the safety precautions described in the

manual been implemented?

2.

Does the oil piping conform to the recommen-

dations of your Oil Supply Company?

3.

Has the oil piping been tested for leaks?

4.

Is the clearance between the water heater

and combustible construction as per specifica-

tions?

5.

Is the water piping correctly connected? Are

you certain that there are no leaks?

6.

Is the water heater filled with water?

7.

Is the cold water supply valve open?

8.

Is the flue pipe installed properly and are the

vertical and horizontal runs properly support-

ed?

9.

Is the draft regulator intake opening unob-

structed?

10.

Is the T&P valve installed? Are the drain pipe

(if installed) and T&P valve unobstructed?

11.

Is a drain pan installed (if required) with a

proper overflow pipe, directed to a drain?

12.

Have you taken steps to prevent water dam-

age in case of leaks?

13.

Does the area around the water heater have

adequate ventilation?

14.

Air moving device does not create negative

pressure?

15.

Flammable vapours and materials are not

placed in the proximity of the water heater?

If the answer to all the above is “Yes”, proceed with the

“Startup” instructions.

IV) OPERATION

This manual is related to the following products: