beautypg.com

Machine data sheet, Performance curve – Grizzly G0671 User Manual

Page 34

background image

-32-

Model G0671/G0672/G0673 (Mfg. Since 1/13

Note: When calculating static pressure loss to
determine if multiple lines can be left open at the
same time, only include the main line numbers
once.

5. Compare the total static pressure loss for

that line to the closest CFM given in the

Performance Curve section on the Machine

Data Sheet (located toward the front of this
manual).

Example: go to the Model g0671 data sheet
Performance Curve section (see

Page 4) or

see figure 35 and find 4.4 on the pressure
axis, then go up the CFM axis to the closest
value—approximately 3550 CFM, as shown
in

figure 35.

the 3550 CFM (

figure 35) for the static pres-

sure loss of the line connected to the router is
well above the 220 CFM requirement of that
machine.

figure 34. example list for totaling sp loss.

Main Line

6" Rigid Pipe (0.037) at 20'

................ 0.740

Branch Line

4" Rigid Pipe (0.075) at 10'

................ 0.750

4" Flex Pipe (0.28) at 5' ........................ 1.400

Elbows/Branches

6" 45˚ Y-Branch

................................ 0.329

4" 45˚ Elbow ........................................ 0.225

Additional Factors

Seasoned Filter

................................ 1.000

Total Static Pressure Loss ................ 4.444

—if the CFM for your static pressure loss

is above the requirement of the machine
connected to the end of that branch line,
then dust collection will most likely be
successful. Congratulations! you've just
designed your own dust system. refer to
the

accessories section on Page 35 to

start buying the components necessary to
make your system a reality.


—if the CFM for your static pressure loss is

below the requirement of the machine, then
that line will not effectively collect the dust.
you must then modify some of the factors
in that line to reduce the static pressure
loss. some of the ways to do this include:
1) installing larger duct, 2) reducing amount
of flexible duct used, 3) increasing machine
dust port size, 4) moving machine closer to
dust collector to eliminate duct length, and
5) reducing 90˚ elbows or replacing them
with 45˚ elbows

model G0671

4 HP dUST ColleCToR

Customer Service #: (570) 546-9663 • To Order Call: (800) 523-4777 • Fax #: (800) 438-5901

mACHINe dATA

SHeeT

101

1

/

8

"

73

7

/

8

"

Ш10"

31

3

/

8

"

47

5

/

8

"

47

1

/

4

"

47

1

/

4

"

Ш23

5

/

8

"

Ш23

5

/

8

"

6

5

/

8

"

101

1

/

8

"

73

7

/

8

"

Ш10"

31

3

/

8

"

47

5

/

8

"

47

1

/

4

"

47

1

/

4

"

Ш23

5

/

8

"

Ш23

5

/

8

"

6

5

/

8

"

Test run using 30 micron upper and lower bag

4 HP DUST COLLECTOR PERFORMANCE RESULTS
Max CFM Max SP

HP

Volts

Inlet

Impeller

3551.6

13.5

4 HP

220V

10"

14

1

/

2

"

Inlet Dia. (inch)

10"

9"

8"

7"

6"

5"

4"

3"

2"

CFM

3551.6 3454.8 3282.6 2916.6 2475.4 2098.7 1452.9 979.4

484.3

Static Pressure

(Inch/H2O)

4.72

4.82

6.98

8.5

10.3

11.1

12.53

13.2

13.5

Amps

30

29.5

27.5

24

21

16.8

12.5

11

8.6

Air Speed (m/s)

33

32.1

30.5

27.1

23

19.5

13.5

9.1

4.5

Performance Curve

4000
3750
3500
3250
3000
2750
2500
2250
2000
1750
1500
1250
1000

750
500
250

0

0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

9.0

10.0

11.0

12.0

13.0

14.0

CFM

STATIC PRESSURE (Inch/H2O)

Model G0671

Page 3 of 3

figure 35. CFM for static pressure loss of line

connected to g0671 dust collector & router.

4.4 sp loss

Closest

CFM

(3550)

4. total your list, as shown in the example in

figure 34, to come up with your overall static
pressure loss number for that line.

Note: Always account for a seasoned filter,
so you don't end up with a system that only