Test Run
once the assembly is complete, test run your
machine to make sure it runs properly and is
ready for regular operation.
the test run consists of verifying the following: 1)
the motor powers up and runs correctly, and 2)
(Model g0673 only), the motor turns the correct
direction (machine is not wired out of phase).
if, during the test run, you cannot easily locate
the source of an unusual noise or vibration, stop
using the machine immediately, then review the
Troubleshooting on Page 38.
if you still cannot remedy a problem, contact our
tech support at (570) 546-9663 for assistance.
5. listen to and watch for abnormal noises or
actions. the machine should run smoothly
with little or no vibration or rubbing noises.
— strange or unusual noises should be inves-
tigated and corrected before operating the
machine further. always disconnect the
machine from power when investigating or
correcting potential problems.
6. turn the machine OFF by pushing in the red
button on the power switch.
To test run the machine:
1. Make sure you have read the safety instruc-
tions at the beginning of the manual and that
the machine is setup properly.
2. Make sure all tools and objects used during
setup are cleared away from the machine.
3. Connect the machine to the power source.
4. turn the machine ON by pushing in the
green button on the power switch.
7. Model G0673 Only: verify that the power
is not connected out of phase by starting/
stopping the machine and determining if the
motor turns in the correct direction, using the
criteria below:
— if the impeller turns counterclockwise
(when looking down on the inlet port on the
impeller housing), it is turning in the correct
direction.
— if the impeller turns clockwise, it is turning
in the wrong direction. stop the machine,
shut off the power source, then swap any
two of the three power wires that connect
to the machine.