D table 3, R p12 (table 3), Table 3 – GE Autotrol Performa ProSoft 960 Series User Manual
Page 9: Table 3 to
9
Table 3 - Level II Programming Parameters
Parameter
Name
Description
Range of Values
Minimum
Increments
Default
Units of
Measure
Notes
P6
Refill controller
1 to 99
1
33
Enter the value molded into the
end of the refill controller.
P7
Regenerant
draw value
1 to 99
1
25
Select number from Table 4 and
enter that number.
P8
Not used
NA
NA
NA
NA
NA
P9
Backwash time
3 to 30
1
14
Minutes
Skip this parameter to accept the
default or enter a value.
P10
Slow rinse time
8 to 125
1
40
Minutes
Skip this parameter to accept the
default or enter a value.
P11
Fast rinse time
2 to 19
1
4
Minutes
Skip this parameter to accept the
default or enter a value.
P12
Units of Measure
0 to 1
1
0
0 = U.S., 1 = metric. Skip this
parameter to accept U.S. or enter
1 for metric.
P13
Clock mode
0 to 1
1
0
0 = 12-hour clock.
1 = 24-hour clock. Skip this
parameter for a 12-hour clock or
enter 1 for a 24-hour clock.
P14
Calendar
override
0 to 30
1
0
Days
0 = no calendar override. Skip this
parameter for no calendar
override or enter a value.
P15
Reserve type
0 to 3
1
0
0 = variable reserve, 1 = fixed
reserve, 2 = variable reserve with
immediate regen,
3 = fixed reserve with immediate
regen. Skip this parameter to
accept the default or enter a
different reserve type.
P16
Fixed reserve
capacity or initial
average value
0 to 70
1
30
Percent of
capacity
Description depends on the value
entered for P15. Skip this
parameter to accept the default or
enter a different value.
P17
Operation type
0 to 2
1
2
2 = 5-cycle
cocurrent conditioner.
P18
Salt/capacity
change lockout
0 to 1
1
0
0 = none, 1 = salt/capacity change
locked out. Skip this parameter to
accept the default or enter 1 to
lock out salt/capacity change.
P19
Factory defaults
1
99
Loads in a set of default values.
Refer to the Special Notes for
Level II Parameters section in this
manual. Do Not Change.