Table 8 – GE Autotrol Performa ProSoft 960 Series User Manual
Page 15
15
Table 8 - Performa 960 FA Level II Programming Parameters
Parameter
Range of Values
Minimum
Increments
Default
Units of Measure
Notes
Name
Description
P6
Refill controller
1 to 99
1
33
Must be set to 46 for Performa 960
FA operation
P7
Regenerant draw
value
1 to 99
1
25
Select Regenerant Draw value from
Table 9 and enter that number.
P8
Not used
NA
NA
NA
NA
NA
P9
Backwash time
3 to 30
1
14
Minutes
Skip this parameter to accept the
default or enter a value.
P10
Slow Rinse time
8 to 125
1
40
Minutes
Skip this parameter to accept the
default or enter a value.
P11
Fast Rinse time
2 to 19
1
4
Minutes
Skip this parameter to accept the
default or enter a value.
P12
Units of measure
0 to 1
1
0
0 = U.S., 1 = Metric. Skip this
parameter to accept U.S. or enter 1
for Metric.
P13
Clock mode
0 to 1
1
0
0 = 12-hour clock, 1 = 24-hour
clock. Skip this parameter for a 12-
hour clock or enter 1 for a
24-hour clock.
P14
Calendar
override
0 to 30
1
0
Days
0 = no calendar override. Skip this
parameter for no calendar override
or enter a value.
P15
Reserve type
0 to 3
1
0
0 = variable reserve, 1 = fixed
reserve, 2 = variable reserve with
immediate regen, 3 = fixed reserve
with immediate regen. Skip this
parameter to accept the default or
enter a different reserve type.
P16
Fixed reserve
capacity or initial
average value
0 to 70
1
30
Percent of capacity
Description depends on the value
entered for P15. Skip this
parameter to accept the default or
enter a different value.
P17
Operation type
0 to 2
1
2
2 = 5 cycle Cocurrent conditioner
P18
Regen. Dosage/
Capacity change
lock out
0 to 1
1
0
0 = none, 1 = Regenerant Dosage/
Capacity change locked out. Skip
this parameter to accept the
default or enter 1 to lock out
Regenerant Dosage/Capacity
change.
P19
Factory defaults
0 to 3
1
99
Loads in factory default values. Do
not change this parameter.