LOW OR FLUCTUATING OUTPUT

TYPE OF PROBLEM

WHAT TO CHECK

If check is OK, go to next check

WHAT TO DO

When check is not OK refer to this column

Low Output

1. For worn spray tip.

1. Follow Pressure Relief Procedure Warn-

ing, then replace tip. See your separate

gun or tip manual.

2. Verify pump does not continue to stroke when

gun trigger is released.

2. Service pump. See page 26.

3. Filter clogged (If optional filter is installed).

3. Relieve pressure. Check and clean filter.

4. Prime valve leaking.

4. Relieve pressure. Repair prime valve.

5. Suction hose connections.

5. Tighten any loose connections.

6. Electrical supply with volt meter.

Meter must read:

210--255 Vac for 220--240 Vac models.

85--130 Vac for 100--120 Vac models. Low volt-

ages reduce sprayer performance.

6. Reset building circuit breaker; replace

building fuse. Repair electrical outlet or try

another outlet.

7. Extension cord size and length; must be at least

12 gauge wire and no longer than 300 ft. Longer

cord lengths reduce sprayer performance.

7. Replace with a correct, grounded exten-

sion cord.

8. Leads from motor to pressure control circuit

board (35) for damaged or loose wires or con-

nectors. Inspect wiring insulation and terminals

for signs of overheating.

8. Be sure male terminal blades are centered

and firmly connected to female terminals.

Replace any loose terminal or damaged

wiring. Securely reconnect terminals.

9. For loose motor brush leads and terminals. See

page 12.

9. Tighten terminal screws. Replace brushes

if leads are damaged. See page 12.

10.For worn motor brushes which must be 1/4 in. (6

mm) minimum. See page 12.

10. Replace brushes. See page 12.

11. For broken or missing motor brush caps.

11. Replace brushcap if broken. Realign spring

with brush. See page 12.

12.Motor brushes for binding in brush holders. See

page 12.

12.Clean brush holders, remove carbon dust

with small cleaning brush. Align brush lead

with slot in brush holder to assure free verti-

cal brush movement.

13.Low stall pressure.

13. Do either or both:

a. Turn pressure control knob fully

clockwise. Make sure pressure
control knob is properly installed to
allow full clockwise position.

b. Try a new transducer.

14.Motor armature for shorts by using an armature

tester (growler) or perform spin test. See page

12.

14.Replace motor. See page 25.