beautypg.com

GE QS1800V User Manual

Page 24

background image

18

REMEDIES

Measure the current draw to

verify it is below the trip set-

ting. Increase the heater size

or adjust the trip setting to

correspond to the S.F.A. indi-

cated by the motor label.

QVS pumps are designed to

pump water. Consult the fac-

tory for liquids other than

water.

With the pump filled with the

process fluid, use a megohm
meter to measure the resist-

ance between each motor

lead and ground first at low

voltage, then at a potential

between 500 and 1000V if the

low-voltage test indicates an

open circuit. Consult the

motor installation and main-

tenance manual for accept-

able values.

With the circuit de-energized,

check for continuity using an

ohmmeter.

Confirm the circuit is wired for

single-phase or three-phase

power and the motor is

grounded.

Make sure the three legs of

your three-phase power are

balanced within ±5% of each

other.

POSSIBLE CAUSES

Motor starter heater size

too small

Specify gravity of liquid or

viscosity greater than

design

Water short in motor

electrical lead

Bad connection

Motor wired improperly

Three-phase current

imbalance

PROBLEM

Motor runs, then stops

(continued)

T R O U B L E S H O O T I N G G U I D E

This manual is related to the following products: