GENERAL TROUBLESHOOTING

This troubleshooting guide can assist you in identifying common operating problems you
may experience with your machine. The operator can easily correct may of these problems,
however, for those that persist or are not understood you should contact the GE Customer
Support Center. Have the following information available when calling the Customer Support
Center:

1.

Machine installation date

2.

Model number

3.

Serial number

4.

Detailed description of problem.

15

REMEDIES

The pump inlet should be

piped to induce minimal pres-

sure drops through piping

diameter changes, elbows,

instrumentation, etc. QSV

pumps should NEVER be

throttled at the inlet. Check

discharge screen for

obstructions.

Verify no debris is clogging

screen or filter.

Make sure the discharge

valve is open enough to keep

the pump running on the per-

formance curve.

Fluid motion in your inlet pip-

ing may draw air into the

pump if the piping is not

sealed properly. Air bubbles

will be visible in the discharge

line.

POSSIBLE CAUSES

Restrictions in the inlet or

discharge

Inlet strainer/filter plugged

Discharge throttling valve

closed (pump deadheaded)

Air leak in inlet piping

PROBLEM

Low flow

T R O U B L E S H O O T I N G G U I D E