16

REMEDIES

QSV pumps are not designed

to “lift” or “pull” fluid from a

tank. QSV pumps must be fed

with positive pressure [at

least 20 psi (1.4 bar)]. This

may be accomplished either

by having positive head from

the tank or incorporating a

transfer pump.

Make sure the motor is spin-

ning in the proper direction.

Prime the pump by filling all

inlet piping, including the

pump, with the process fluid.

Make sure your pump is oper-

ating within the flow range

specified by the pump per-

formance summary table or

the performance curve

included with the pump.

Verify no debris is clogging

the inlet screen or filter.

Fluid motion in your inlet pip-

ing may draw air into the

pump if the piping is not

sealed properly. Air bubbles

will be visible in the discharge

line.

Make sure the motor is spin-

ning in the proper direction.

Reverse two of the leads if

necessary.

POSSIBLE CAUSES

Suction lift too high

Reverse rotation of motor

Pump not adequately

primed

Excessive flow

Clogged suction into filter or

screen

Air leak in the inlet piping

Reverse rotation of motor

PROBLEM

Low flow

(continued)

T R O U B L E S H O O T I N G G U I D E