beautypg.com

GE Zoneline AZ38H09EAB User Manual

Room air/installation qsart, Az38h09e – ge zoneline, Deluxe series heat pump unit

background image

AZ38H09E – GE Zoneline

®

Deluxe Series Heat Pump Unit

Specification Created 9/04

390523

GE Appliances

Electrical Wiring
All wiring, including installation of receptacle, must be made in

accordance with local electrical codes and regulations.
Note: Aluminum wiring may pose special problems – consult

a qualified electrician.
Grille Options
Stamped Aluminum Grille – RAG60
Exterior Architectural Louvers Durable Polycarbonate:
RAG61 or RAG64 (Beige)

RAG63 or RAG66 (Bittersweet)

RAG62 or RAG65 (Maple) RAG67 (Extruded Aluminum)
Retrofit Kits:
RAK901L – Wall Case Insulation for use with heat pumps.

RAK40 – Deflector Kit to adapt chassis for use with existing

exterior architectural louvered grilles.
Ducted Applications
2800 and 3800 series can be used with ductwork to heat or

cool more than one room. RAK6052 Duct Adaptor is applied

to top of case over air discharge/RAK601 Duct Extension is

applied to right or left of adaptor. Locally fabricated ductwork

may be added to extend to maximum recommended distance

of 15 feet.
Electrical Connection
230/208 volt units may be plugged into a receptacle. 265 volt

units are provided with a junction box and require direct

connection. (NEC Requires 265V Direct Connection) See

Architects and Engineers Design Data Manual for electrical

connection information including use of sub-base for direct

connected units. Installation must comply with local electrical

codes and regulations.
Power Connection kits required on all Zoneline chassis.

A

C

B

Zoneline RAC Wall Installation

Zoneline Wall Install QSart

Wall Case Dimensions

RAB71 Wall Sleeve

Heavy-gauge galvanized steel, with insulation.

A – 42", B – 13-3/4", C – 16"
RAB77 Wall Sleeve

Molded SMC fiberglass-reinforced polyester compound.

A – 42-1/8", B– 13-7/8", C – 16-1/4

Wall Opening Dimensions

Add 1/4" to A and C dimensions for all cut-out size.

RAB71 16-1/4" Min. H x 42-1/4" Min. W

RAB71 available in 16", 24", 28" and 31" depths

RAB77 16-1/2" Min. H x 42-3/8" Min. W

Maximum Cord Extension (in inches)

For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

ge.com or call GE Answer Center

®

service,

800.626.2000.

SIDE

VIEW

Inside

Room

Cabinet

Outside

58

21

Grille

7-1/8

RAB71A = 16
RAB77A = 16-1/4

RAB71A = 20-7/8
RAB77A = 21

Room Air/Installation QSart

265 Volt Sub-Base Connected Units

Sub-Base

Power

Connection Kit

Electric

Heater Watts

Electric

Heat Amps

Min. Circuit

Protection

(Amps)

RAK204E15

RAK5172

2,550

10.3

15

RAK204E20

RAK5202

3,450

13.7

20

RAK204E30

RAK5302

5,000

19.6

30

This manual is related to the following products: