Notice, 220v operation – Grizzly G0518 User Manual
Page 9
G0518 Drum / Flap Sander
-7-
Figure 2.
NEMA 6-15 plug and
grounded outlet.
Amperage Draw
The Model G0518 can be rewired to operate at
220V, with an amperage draw of approximately
6A.
Plug Type
If the Model G0518 is rewired to operate at 220V,
the existing plug must be replaced with a NEMA
6-15 plug. A suitable 220V power source must be
used along with a properly grounded outlet. See
Figure 1
for a NEMA 6-15 plug and grounded
outlet.
Circuit Breaker Requirements
We recommend operating the machine on a ded-
icated circuit. Because the machine draws 6A
when operated at 220V, use a 10A double-pole
circuit breaker. Circuit breakers rated any higher
are not adequate to protect the circuit from over-
heating and fire.
Your Circuit Capacity
Always check to see if the wires in your circuit are
capable of handling the amperage draw from
your machine, as well as any other machines that
could be operating on the same circuit. If you are
unsure, consult a qualified electrician.
If the circuit breaker trips or the fuse blows regu-
larly, your machine may be operating on a circuit
that is close to its amperage draw capacity.
However, if an unusual amperage draw does not
exist and a power failure still occurs, contact a
qualified electrician or our service department.
Serious personal injury could occur if you
connect your machine to the power source
before you have completed the assembly
process. DO NOT connect the machine to
the power source until instructed to do so.
NOTICE
If a 220V power source will be used, rewire
the power switch before assembling the
motor to the stand. See Page 26 for complete
instructions on rewiring the sander.