beautypg.com

Wiring diagrams, Iring, Iagram – Goodman Mfg GPH13M User Manual

Page 37: Roduct, Pecifications, Arning

background image

P

roduct

S

PecificationS

P

roduct

S

PecificationS

SS-GPH13M

www.goodmanmfg.com

37

Wiring

is subject

to change. Al

wa

ys

refer to the wiring

diag

ram

or the

unit

for

the most up-to-da

te

wiring

.

W

arning

High

Voltage:

Disconnect

all power

bef

or

e

ser

vicing

or

installing

this

unit.

Multiple

power

sour

ces ma

y be pr

esent.

Failur

e to do so ma

y cause pr

operty damage, per

sonal injur

y, or dea

th.

SEE NOTE 4

FC

SEE
NOTE 2

EM

M1

COM

TR

24V

208-240

NC

EBTDR

N

O

3

CONTROL
BOX

240

PU

208-240/1/60

SUPPLY VOLTAGE

C

COMP

C

S.A.

S

T1

R

FC

L1

BR

DF1

C

SEE NOTE 5

H

F

RCCF

CM

HVDR

T2

CH

C

DF2

L2

BK

RD

RD

RD

K1

K1

M1

NOTE #2

XFMR-C

PU



C

BL

XFMR-R

R

G

EBTDR

GR

COM

NC

RD

NO

RD

2

24V

BL

208

TR

C

BK

1

PU

COMP

CM

BR

BR

PU

4

1

PLF

PU

BK

YL

S

BK

RD

BK

5

6

2

3

C R

RD

OR

BL

BR

WH

GR

YL

R

O

C

W2

W1

G

Y

A
T

O

T

S

M

R

E

H

T

T2

T1

RD

SEE NOTE 4

PU

BL

L1

GND

C

L2

BK

6
0

/

/

1

0

4

2

-

8

0

2

HIGH

(TRANS240V)

PU

(M1) RD

BR

FC

LOW

OPTIONAL

2 SPEED

BR

EM

3 SPEED

EM

M2



M2

7

8

9

PU

BL

BR

0140G01745-B

RD

RD

BK

BK

RD

PU

BK

RD

DFT

RVC

COMPONENT LEGEN D

BR
C
CCR
CH
CHS
CM
COMP
DC
DFT
EBTDR
EM
FC
GND
HPS
HVDR
LPS
LVDR
LVJB
PLF
RVC
RCCF

SA
TR

BLOWER INTERLO CK RELAY
CONTACTOR
COMPRESSOR CONTACTOR R ELAY
CRANKCASE HEATER
CRANKCASE HEATER SW ITCH
CONDENSER MOTOR
COMPRESSOR
DEFROST CONTROL
DEFROST THERMOSTAT
ELECTRO NIC BLOWER TIME DELA Y RELAY
EVAPORATOR MOTOR
FAN CAPACITOR
EQUIPMENT GROUND
HIGH PRESSURE SW ITCH
HIGH VOLTAGE D EFROST RELAY
LOW PRESSURE SW ITCH
LOW VOLTAGE DEFR OST RELAY
LOW VOLTAGE JUN CTION BO X
FEMALE PLUG / CO NNECTOR
REVERSING VALVE COIL
RUN CAPACITOR FOR
COMPRESSOR AND FAN
START ASSIST
TRANSFO RMER

WIRE CODE

BK BLACK
BL BLUE
BR BROWN
GR GRE EN
OR ORA NGE
PU PU RPLE
RD RED
WH WHITE
YL YELLOW

FACTORY WIRING

LINE VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH
VOLTAGE

FIELD WIRING

HIGH VOLTAGE
LOW VOLTAGE

++

EBTDR

R

G

C

EBTDR

3

1

2

LVJB

OR

BL

BL

SEE NOTE
#6

THERMOSTAT

PU

RCCF



SA

YL

H

C

F

BR

BL

BR

BK

SEE NOTE # 5

R

W2

O

W1

G

C

P
L
F

6

5

4

C

Y

2

4

SEE UNIT RATING PLATE FOR TYPE AND SIZE

OF OVER CURRENT PROTECTION

NOTES:

1. REPLACEMENT WIRE MUST BE SA ME SIZE A ND TYPE IN SULATION AS
ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR O NLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED REPLACE LEA D ON EBTDR
"COM" WITH LEAD O N EBTDR "M1" OR "M2".
3. CRANKCASE HEATER A ND CRANKCASE HEATER SW ITCH FACTOR Y
EQUIPPED WHEN REQUIRED.
4. FOR 208 VOLT TRANSFO RMER OPERATION MOV E PURPLE WIRES
FROM TERMINAL 3 TERMINAL 2 ON TRANSFO RMER.
5. START ASSIST FACTORY EQUIPPED WHEN REQUIRED.
6. USE COPPER CONDUCTORS O NLY ++ USE N.E.C. CLAS S 2 WIRE.
7. DOUBLE POLE CO NTACTOR S HOWN. SINGLE POLE C ONTACTOR
COULD B E FACTOR Y EQUIPPED AS AN ALTERN ATE CONFIG URATION.
8. COMMON SIDE OF CO NTACTOR C AN NOT BE G ROUNDED OR
CONNECTED TO AN Y OTHER COMMON (24V).

(COM) BK

4

2

1

3

3

1

3

1

BR

P
L
F

RD

HPS

CHS

LPS

SEE NOTE 3

PU

CH

GR

BK

BK

BK

RD

RD

CHS

PU

YL/PK

YL/PK

YL

PU

SEE NOTE # 8

SEE NOTE # 7

SEE NOTE # 3

SEE NOTE # 3

BL/PK

BL/PK

YL

YL

HPS

DC

DFT

Y

C

R

RVC

LPS

CNT

R-PS1

PS2

R

W

O

R-DFT

DFT

O-RV

C-RV

2 POLE ONLY
SEE NOTE 7

PU

BK

RD

WH

WH

BK

YL

PU

PU

BK

BL

BK

BK

RD

PS2

C

C

R

C

Y

Y

R

-PS1

R-

DF

T

D

FT

0

CNT

CCR

HVDR

LVDR

W

C-RV

0-RV

0

D

F2

D

F1

R

DC

BK

OR

RD

W

iring

D

iagram

gPH1324-42m41a* & gPH1324-30, 42m41C*